Retrigging The Logging Ni Community

Solved Triggered Logging Ni Community
Solved Triggered Logging Ni Community

Solved Triggered Logging Ni Community The screenshot below shows how you can re trigger every time channel cdaq1\ai0 goes above 9v and then it will log for 1 minute (you could make the stop based on a voltage value as well). I'm running cycle testing using the "enable re triggering" option in flexlogger, under logging trigger. it works well, but i have to manually stop the test and the output is one single tdms file.

Solved Triggered Logging Ni Community
Solved Triggered Logging Ni Community

Solved Triggered Logging Ni Community Greetings. i am using a pxi 6289 and i need to generate a fast continous pulse traing that is synced with an external clock. i have foudn several examples which at the core all have same base. use a counter to generate a finite number of pulses that is trigered from the external clock and then retri. You create a trigger when you set the conditions in the logging specification. you can enable or disable the trigger from any project document by using the triggers toggle in the toolbar. This article will show you how to start your logging specifications, and how you can configure the triggering options for your logging specification. this article will use the 'engine demo' shipping example to create, start and trigger the logging specifications. Open a service request. the ni community is part of the vibrant ni ecosystem. this is your place to network, ask questions, and collaborate on code with users all over the world. learn how to use the ni community as well as read the latest news and announcements.

Solved Triggered Logging Ni Community
Solved Triggered Logging Ni Community

Solved Triggered Logging Ni Community This article will show you how to start your logging specifications, and how you can configure the triggering options for your logging specification. this article will use the 'engine demo' shipping example to create, start and trigger the logging specifications. Open a service request. the ni community is part of the vibrant ni ecosystem. this is your place to network, ask questions, and collaborate on code with users all over the world. learn how to use the ni community as well as read the latest news and announcements. I implemented the solution from zyong of the ni community, that is to record the trigger as an additional analog input and then perform an offline processing to select the samples from my analog input of interest based on the analog input triggers. Flexlogger is application software for quick sensor configuration and data logging of mixed signals to verify electromechanical systems, all without programming. you can use the flexlogger discussion forum to engage with the ni community to discuss product features and solve data logging challenges. Hello together, while using the stimulus profile editor i have the following problem: when i set the trigger condition to "out of limits" and the "high" and "low limit", the triggered logging starts immediately, so that the measurement is false. normally i set up a value which cannot be reached, s. Connect the analog signal to ai0 and the trigger signal to ai1. add both channels to the same task to synchronize them. usb 6002 supports an aggregated sample rate of 50ks s so you would get 25ks s, which is roughly 4% of the timing error for the trigger signal of 1ms.

Comments are closed.